To update parameters of fuel fillings/thefts detection, use the command unit/update_fuel_level_params:
svc=unit/update_fuel_level_params¶ms={"itemId":<long>, "flags":<uint>, "ignoreStayTimeout":<uint>, "minFillingVolume":<double>, "minTheftTimeout":<uint>, "minTheftVolume":<double>, "filterQuality":<ubyte>, "fillingsJoinInterval":<uint>, "theftsJoinInterval":<uint>, "extraFillingTimeout":<uint> }
Parameters
Name | Description |
---|---|
itemId | unit ID |
flags | flags of fillings and thefts (see Fuel consumption) |
ignoreStayTimeout | ignore the messages after the start of motion, sec |
minFillingVolume | minimum fuel filling volume, litres |
minTheftTimeout | minimum stay timeout to detect fuel theft, sec |
minTheftVolume | minimum fuel theft volume, litres |
filterQuality | filter quality (0..255) |
fillingsJoinInterval | timeout to separate consecutive fillings, sec |
theftsJoinInterval | timeout to separate consecutive thefts, sec |
extraFillingTimeout | timeout to detect final filling volume, sec |
Response
{} /* empty object if execution successful, if not - error code */