To update calculation parameters for counters, use the command unit/update_calc_flags:
svc=unit/update_calc_flags¶ms={"itemId":<long>, "newValue":<uint>}
Parameters
Name | Description |
---|---|
itemId | unit ID |
newValue | new counter calculation flags (see below) |
Counter calculation flags:
Flag | Description |
---|---|
0x000 | Mileage counter: GPS |
0x001 | Mileage counter: Mileage sensor |
0x002 | Mileage counter: Relative odometer |
0x003 | Mileage counter: GPS + engine ignition sensor |
0x010 | Engine hours counter: Engine ignition sensor |
0x020 | Engine hours counter: Absolute engine hours sensor |
0x040 | Engine hours counter: Relative engine hours sensor |
0x100 | Auto calculation of mileage from new messages |
0x200 | Auto calculation of engine hours from new messages |
0x400 | Auto calculation of GPRS traffic |
Response